Por favor, use este identificador para citar o enlazar este ítem: http://www.repositorio.ufop.br/jspui/handle/123456789/10534
Título : Caracterização do feltro de lã para aplicação em produtos ortopédicos e hospitalares.
Autor : Santos, Heloisa Nazaré dos
metadata.dc.contributor.advisor: Lana, Sebastiana Luiza Bragança
Martins Neto, José Henrique
Palabras clave : Feltro de lã
Vestuário hospitalar
Palmilha
Ortopédico
Fecha de publicación : 2018
metadata.dc.contributor.referee: Lana, Sebastiana Luiza Bragança
Ramos, Júlia Baruque
Garrido, Carlos Antônio
Gouveia, Antônio Maria Claret de
Martins Neto, José Henrique
Citación : SANTOS, Heloisa Nazaré dos. Caracterização do feltro de lã para aplicação em produtos ortopédicos e hospitalares. 2018. 297 f. Tese (Doutorado em Engenharia de Materiais) – Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2018.
Resumen : O feltro de lã é um material que vem sendo utilizado nas indústrias de artefatos. No setor do vestuário, o feltro tem se limitado à aplicação em chapéus e poucos calçados para inverno. O feltro é um material sustentável proveniente da lã de ovinos, com potencial para utilização em vários produtos. Esses fatores motivaram a realização desta pesquisa para avaliar as características e o desempenho da matéria-prima para utilização no segmento médico hospitalar. O objetivo deste trabalho foi investigar o uso do feltro de lã para aplicação em lençóis e fronhas de uso hospitalar, e palmilhas para uso terapêutico. A metodologia experimental foi dividida em: "Testes de Caracterização" para determinação das propriedades termofísicas, químicas e outras variáveis do comportamento do material; "Testes de Aplicação" para determinação do desempenho do produto. Os "Testes de Caracterização" foram realizados no feltro de lã antes e depois de ele passar por lavagem nas máquinas extratora, túnel e a seco. Também foi realizada uma caracterização dos materiais feltro sintético 100% poliéster, tecido de algodão 100% e tecido misto (67% algodão / 33% poliéster). Esses testes foram: Mecânicos; Inflamabilidade; Químicos; Colorimetria; Microscopia Eletrônica de Varredura - MEV. Os Testes de Aplicação foram: Termografia; Análise Microbiana; Análise da Adaptabilidade dos lençóis, fronhas e palmilhas de feltro. Os resultados dos testes de caracterização mostraram que o feltro de lã possui boa resistência mecânica à tração, ao rasgo e ao esgarçamento, pilling comparável ao dos demais materiais, melhor resistência à propagação de chama, excelente repelência a dois agentes químicos e a água líquida, e baixa repelência ao óleo. As análises do MEV mostraram a estrutura escamosa da fibra do feltro de lã diferente da fibra lisa do feltro sintético. Nos testes de caracterização do feltro de lã após lavagem, foi verificado que as máquinas extratora e a seco apresentaram maiores resistências mecânicas, o pilling não apresentou alteração significativa, a repelência a dois agentes químicos não variou para as máquinas extratora e a seco. A concentração de lanolina retida no feltro mostrou ser maior na lavagem a seco, não apresentando variação após o primeiro de um total de cinco ciclos de lavagem. O processo de lavagem na máquina a seco mostrou ser menos agressivo de todas as máquinas, preservando as cores do feltro além de não as degradar após o primeiro dos cinco ciclos de lavagem. A análise de MEV mostrou melhor conservação das cutículas no processo de lavagem a seco. Os resultados dos testes de aplicação mostraram no ensaio de termografia não haver diferença entre as temperaturas nas palmilhas de Feltro de lã e de EVA (Etileno Acetato de Vinila). A análise microbiana mostrou a ineficiência do agente bactericida / fungicida aplicado nas palmilhas. Os testes da adaptabilidade dos lençóis, fronhas e palmilhas de feltro mostraram boa adaptabilidade quanto a percepção de conforto dos usuários. Conclui-se que o feltro de lã é um material versátil com características e propriedades que o habilitam como material resistente e multifuncional para ser aplicado em produtos do vestuário hospitalar e ortopédicos.
metadata.dc.description.abstracten: The wool felt is a material that has been used in artifact industries. In the clothing sector felt has been limited for applications in hats and few shoes for wintertime. Felt is a sustainable material obtained from sheep wool with potential to be used in various products. These factors motivated the conduction of this research to evaluate the characteristics and performance of this raw material for utilization in the hospital sector. The goal of this work is to investigate the utilization of the wool felt for application in sheets and pillowcases used in hospitals, and insoles for therapeutic use. The experimental methodology has been divided in: "Characterization Tests" for determination of thermo physical and chemical properties and other variables referent to the material behavior; "Application Tests" for evaluation of the product behavior. The "Characterization Tests" have been performed in the wool felt before and after it has been washed in the extractor, tunnel and dry washing machines. Additionally, it has been performed the characterization of the synthetic felt 100%, the cotton 100% textile and the mixing textile (67% cotton / 33 polyester). These tests were: Mechanicals; Flammability; Chemicals; Colorimetry; Sacaning Electron Microscope - SEM". The "Application Tests" were: Termography, Microbial Analysis and Analysis of the adaptability of sheets, pillowcases and insoles. The results of the "Characterization Tests" showed that the wool felt has good mechanical resistance to traction, to the tear and to the slippage, pilling was comparable to the other materials, better resistance to fire propagation, excellent repellency to two chemical agents and liquid water, and low resistance to oil. SEM analysis showed a flaky fiber appearance for the wool felt different from the plain fiber of the synthetic felt. In the characterization tests after washing it was verified that the extractor and dry machines showed better mechanical resistances, the pilling did not present significant change and the repellence to two chemical agents did not modify for both machines. The lanolin retained in the felt showed to be highest for the dry washing and did not present variation after the first of a total of five washing cycles. The washing process with the dry washer pointed out to be less destructive, preserving the wool felt colors and not degrading them after the first of a total of five washing cycles. The SEM analysis showed the better conservation of the cuticles during the dry washing process. The results of the application tests using thermography showed there was no temperature difference for the insoles of wool felt and EVA (Ethylene-vinyl acetate). The microbial analysis showed the inefficiency of the bactericidal / fungicidal agent applied in the insoles. The adaptability tests of the sheets, pillowcases and insoles showed good suitability regarding the comfort sensation by the users. As conclusion the wool felt is a versatile material due to its characteristics and properties that make it a resistant and functional material, enabling it to be recommended for application in clothing and orthopedic products of the hospital sector.
Descripción : Programa de Pós-Graduação em Engenharia de Materiais. Departamento de Engenharia Metalúrgica, Escola de Minas, Universidade Federal de Ouro Preto.
URI : http://www.repositorio.ufop.br/handle/123456789/10534
metadata.dc.rights.license: Autorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 12/11/2018 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais nem a adaptação.
Aparece en las colecciones: REDEMAT - Doutorado (Teses)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TESE_CaracterizaçãoFeltroLã.pdf14,55 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons