Use este identificador para citar ou linkar para este item:
http://www.repositorio.ufop.br/jspui/handle/123456789/13641
Título: | Impedimetric immunosensor for rapid and simultaneous detection of chagas and visceral leishmaniasis for point of care diagnosis. |
Autor(es): | Cordeiro, Taís Aparecida Reis Martins, Helen Rodrigues Franco, Diego Leoni Santos, Fred Luciano Neves Celedon, Paola Alejandra Fiorani Cantuária, Vinícius Lopes Lana, Marta de Reis, Alexandre Barbosa Ferreira, Lucas Franco |
Palavras-chave: | Dual detection Electropolymerization |
Data do documento: | 2020 |
Referência: | CORDEIRO, T. A. R. et al. Impedimetric immunosensor for rapid and simultaneous detection of chagas and visceral leishmaniasis for point of care diagnosis. Biosensors & Bioelectronics, v. 169, p. 112573, 2020. Disponível em: <https://www.sciencedirect.com/science/article/abs/pii/S0956566320305650?via%3Dihub>. Acesso em: 10 jun. 2021. |
Resumo: | In this work, a dual detection system based on an impedimetric immunosensor was developed for the first time for the simultaneous detection of anti-Trypanosoma cruzi and anti-Leishmania infantum antibodies in human and dog serum samples. The IBMP 8.1 and rLci1A/rLci2B recombinant antigens were immobilized over the surface of dual screen-printed carbon electrodes (W1 and W2) modified with poly (4-hydroxyphenylacetic acid). Under optimized conditions, the immunosensor recognized specific interactions for anti-T. cruzi antibodies up to a dilution of 1:10,240 and for anti-L. infantum up to 1:5120 in canine serum samples. Relative standard deviation (RSD) values of 2.8% for W1 and 3.6% for W2 were obtained for T. cruzi (W1) and L. infantum antigen (W2) samples in three different electrodes for 3 days (n = 9). The immunosensor was stored at 4 ◦C for 8 weeks, with activity retention of 70.2% in W1 and 78.2% in W2. The results using the recombinant proteins revealed that all antigens discriminated between negative and positive samples (p < 0.0001) in both dog and human groups, as well as no cross-reactivity could be detected among sera with other infections. With this approach, immunosensor-based diagnostic tests achieved 100% accuracy, suggesting that the antigens are eligible to enter Phase-II studies. |
URI: | http://www.repositorio.ufop.br/jspui/handle/123456789/13641 |
Link para o artigo: | https://www.sciencedirect.com/science/article/abs/pii/S0956566320305650?via%3Dihub |
DOI: | https://doi.org/10.1016/j.bios.2020.112573 |
ISSN: | 0956-5663 |
Aparece nas coleções: | DEACL - Artigos publicados em periódicos |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
ARTIGO_ImpedimetricImmunosensorRapid.pdf Restricted Access | 4,41 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.