Use este identificador para citar ou linkar para este item: http://www.repositorio.ufop.br/jspui/handle/123456789/12703
Registro completo de metadados
Campo Dublin CoreValorIdioma
dc.contributor.authorMiranda, Augusta Martinelli-
dc.contributor.authorAssis, Paulo Santos-
dc.contributor.authorBrooks, Geoffrey Alan-
dc.contributor.authorRhamdhani, Muhammad Akbar-
dc.contributor.authorFontana, Andrea-
dc.contributor.authorKing, Alister-
dc.contributor.authorSanders, Gerald-
dc.contributor.authorMoreira, Gabriela Paula da Costa-
dc.date.accessioned2020-09-08T21:01:17Z-
dc.date.available2020-09-08T21:01:17Z-
dc.date.issued2019-
dc.identifier.citationMIRANDA, A. M. et al. Monitoring of less-common residual elements in scrap feeds for EAF steelmaking. Ironmaking & Steelmaking, v. 46, n. 7, p. 598–608, maio 2019. Disponível em: <https://www.tandfonline.com/doi/full/10.1080/03019233.2019.1601851>. Acesso em: 10 mar. 2020.pt_BR
dc.identifier.issn1743-2812-
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/12703-
dc.description.abstractThe steel scrap quality is classified according to the amount of residual elements. However, there is a limited analysis of some of the less common residual elements such as antimony (Sb), tungsten (W), cobalt (Co), nickel (Ni) and molybdenum (Mo) mixed with steel scrap received by steel plants. This paper reports a historical analysis of these elements in the steel compositions from two steel plants, located in different regions, during 2011 to 2018, analysing around 21000 heats. The concentration of W and Sb dropped by 0.002%, due to the increasing recovery of non-ferrous metals from mixed scrap. It was found that the calibration and maintenance of the spectrometer used to analysis had a direct impact on the results. The presence of Sb, W and Co in the steel indicates contamination from other materials, since 80% of the use of these elements is in applications associated with non-ferrous materials. This is the first analysis of these elements in steel scrap reported the literature and the conclusion of the study is that more attention should be paid to monitor less common residuals elements, because analysis of these elements can provide information about the quality of the metal scrap.pt_BR
dc.language.isoen_USpt_BR
dc.rightsrestritopt_BR
dc.subjectSteel scrappt_BR
dc.subjectQuality controlpt_BR
dc.subjectElectrical arc furnacept_BR
dc.titleMonitoring of less-common residual elements in scrap feeds for EAF steelmaking.pt_BR
dc.typeArtigo publicado em periodicopt_BR
dc.identifier.uri2https://www.tandfonline.com/doi/full/10.1080/03019233.2019.1601851pt_BR
dc.identifier.doihttps://doi.org/10.1080/03019233.2019.1601851pt_BR
Aparece nas coleções:DEMET - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_MonitoringCommonResidual.pdf
  Restricted Access
2,3 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.