Use este identificador para citar ou linkar para este item: http://www.repositorio.ufop.br/jspui/handle/123456789/4264
Título: Development of a fluorescent based immunosensor for the serodiagnosis of canine Leishmaniasis combining immunomagnetic separation and flow cytometry.
Autor(es): Sousa, Susana
Cardoso, Luís
Reed, Steven G.
Reis, Alexandre Barbosa
Martins Filho, Olindo Assis
Silvestre, Ricardo
Silva, Anabela Cordeiro da
Palavras-chave: Flow cytometry
Canine leishmaniasis
Data do documento: 2013
Referência: SOUSA, S. et al. Development of a fluorescent based immunosensor for the serodiagnosis of canine Leishmaniasis combining immunomagnetic separation and flow cytometry. PLoS Neglected Tropical Diseases, v. 7, p. e2371, 2013. Disponível em: <http://www.plosntds.org/article/info%3Adoi%2F10.1371%2Fjournal.pntd.0002371>. Aceso em: 12 ago. 2014.
Resumo: An accurate diagnosis is essential for the control of infectious diseases. In the search for effective and efficient tests, biosensors have increasingly been exploited for the development of new and highly sensitive diagnostic methods. Here, we describe a new fluorescent based immunosensor comprising magnetic polymer microspheres coated with recombinant antigens to improve the detection of specific antibodies generated during an infectious disease. As a challenging model, we used canine leishmaniasis due to the unsatisfactory sensitivity associated with the detection of infection in asymptomatic animals where the levels of pathogen-specific antibodies are scarce. Methodology: Ni-NTA magnetic microspheres with 1,7 mm and 8,07 mm were coated with the Leishmania recombinant proteins LicTXNPx and rK39, respectively. A mixture of equal proportions of both recombinant protein-coated microspheres was used to recognize and specifically bind anti-rK39 and anti-LicTNXPx antibodies present in serum samples of infected dogs. The microspheres were recovered by magnetic separation and the percentage of fluorescent positive microspheres was quantified by flow cytometry. Principal Findings: A clinical evaluation carried out with 129 dog serum samples using the antigen combination demonstrated a sensitivity of 98,8% with a specificity of 94,4%. rK39 antigen alone demonstrated a higher sensitivity for symptomatic dogs (96,9%), while LicTXNPx antigen showed a higher sensitivity for asymptomatic (94,4%). Conclusions: Overall, our results demonstrated the potential of a magnetic microsphere associated flow cytometry methodology as a viable tool for highly sensitive laboratorial serodiagnosis of both clinical and subclinical forms of canine leishmaniasis.
URI: http://www.repositorio.ufop.br/handle/123456789/4264
DOI: https://doi.org/10.1371/journal.pntd.0002371
ISSN: 1935-2735
Licença: Os trabalhos publicados na Plos one estão sob Licença Creative Commons que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e licenciante. Não permite o uso para fins comerciais nem a adaptação. Fonte: Plos one <https://www.plos.org/open-access>. Acesso em: 03 jan. 2017.
Aparece nas coleções:DEACL - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_DevelopmentFluorescent Based.pdf458,54 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.