Use este identificador para citar ou linkar para este item: http://www.repositorio.ufop.br/jspui/handle/123456789/13590
Registro completo de metadados
Campo Dublin CoreValorIdioma
dc.contributor.authorDamasceno, Vinicius de Oliveira-
dc.contributor.authorLima, Jorge Roberto Perrout de-
dc.contributor.authorGonçalves, Reginaldo-
dc.contributor.authorVianna, Jeferson Macedo-
dc.contributor.authorWerneck, Francisco Zacaron-
dc.contributor.authorAmorim, Paulo Roberto-
dc.contributor.authorLima Júnior, Dalton-
dc.contributor.authorLamounier, Joel Alves-
dc.date.accessioned2021-08-25T15:00:16Z-
dc.date.available2021-08-25T15:00:16Z-
dc.date.issued2021pt_BR
dc.identifier.citationDAMASCENO, V. de O. et al. Concurrent validity and reliability of 3-day physical activity recall on daily energy expenditure in children and adolescents. Human Movement, v. 22, n. 2, p. 93-101, 2021. Disponível em: <https://www.termedia.pl/Concurrent-validity-and-reliability-of-3-day-physical-activity-recall-on-daily-energy-expenditure-in-children-and-adolescents,129,42104,0,1.html>. Acesso em: 10 jun. 2021.pt_BR
dc.identifier.issn1899-1955-
dc.identifier.urihttp://www.repositorio.ufop.br/jspui/handle/123456789/13590-
dc.description.abstractPurpose. The aim of this study was to validate the 3-Day Physical Activity Recall (3DPAR) for measuring daily energy expenditure in children and adolescents. Methods. Children and adolescents, a total of 148 participants, were recruited in 10 schools. The data collection was carried out in a period of 11 months. The measurements of weight, skinfold, and circumferences were performed. After the anthropometric assessment, an accelerometer was put on and the participant remained with the electrodes during 5 days. On the fifth day, the accelerometer was taken off and 3DPAR was applied. After 1 week of the study (eighth day), 3DPAR was applied again for testing reliability. Results. In the analysis of reliability and internal consistency, Cronbach’s alpha was 0.73 for the first assessment of 3DPAR and 0.83 for the second one. The consistency of the values estimated by 3DPAR yielded Cronbach’s alpha of 0.89 in the first assessment and 0.83 in the second one. The correlations and the coefficient of determination between 3DPAR and the accelerometer were considered moderate and significant (r = 0.645, p < 0.001). Conclusions. 3DPAR presented satisfactory reliability and moderate correlations with the criterion measurement in children and adolescents aged 10–12 years.pt_BR
dc.language.isoen_USpt_BR
dc.rightsabertopt_BR
dc.subjectObesitypt_BR
dc.subjectQuestionnairept_BR
dc.subjectSelf-reportpt_BR
dc.titleConcurrent validity and reliability of 3-day physical activity recall on daily energy expenditure in children and adolescents.pt_BR
dc.typeArtigo publicado em periodicopt_BR
dc.rights.licenseThis is an Open Access journal distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs (CC BY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode), allowing third parties to download and share its works but not commercially purposes or to create derivative works. Fonte: Human Movement <https://www.termedia.pl/Concurrent-validity-and-reliability-of-3-day-physical-activity-recall-on-daily-energy-expenditure-in-children-and-adolescents,129,42104,1,1.html>. Acesso em: 25 jun. 2021.pt_BR
dc.identifier.doihttps://doi.org/10.5114/hm.2021.100018pt_BR
Aparece nas coleções:DEEFD - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_ConcurrentValidityReliability.pdf7,46 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.