Use este identificador para citar ou linkar para este item: http://www.repositorio.ufop.br/jspui/handle/123456789/12881
Registro completo de metadados
Campo Dublin CoreValorIdioma
dc.contributor.authorFogli, Gabriel Azevedo-
dc.contributor.authorValle, Rodolfo Lacerda-
dc.contributor.authorAlmeida, Pedro Machado de-
dc.contributor.authorBarbosa, Pedro Gomes-
dc.date.accessioned2020-10-24T15:46:39Z-
dc.date.available2020-10-24T15:46:39Z-
dc.date.issued2019pt_BR
dc.identifier.citationFOGLI, G. A. et al. A simple dead-time compensation strategy for grid-connected voltagesourced converters semiconductor switches. Electric Power Systems Research, v. 174, n. 105853, set. 2019. Disponível em: <https://www.sciencedirect.com/science/article/abs/pii/S037877961930166X>. Acesso em: 10 mar. 2020.pt_BR
dc.identifier.issn0378-7796-
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/12881-
dc.description.abstractThis paper presents a simple strategy to compensate the distorted currents synthesized by a grid-connected voltage source converter due to dead-time, turn-on and turn-off time delays of the semiconductor switches. The algorithm consider only the polarity of the fundamental component of the currents flowing through the converter terminals and the values of the time delays and voltage drops supplied by the manufacturers to the semiconductors devices. The presented compensation belongs to the group classified as average value compensation technique methodology since it does not change the pulse pattern of the converter's semiconductor switches. A simplified mathematical description of the effects caused by these unwanted time delays is presented and used to derive a correction factor to be added, in real time, to the converter output controller in order to compensate for its terminal voltages. The asymptotic stability and robustness of the proposed methodology is investigated redrawing the converter current controllers, designed in dq-reference frame, as proportional-resonant ones, in the abc coordinates, and adding the effect of the compensating signal in the feedback loop using the concept of describing function. In addition, the minimum value of the DC bus voltage necessary is also evaluated to ensure the operation of the converter in the linear modulation region when the compensation algorithm is active. Experimental results are presented to validate the theoretical analysis and to demonstrate the effectiveness of the proposed strategy for three different operation conditions of a grid-connected converter: (i) active power injection; (ii) active power consumption and (iii) reactive power support.pt_BR
dc.language.isoen_USpt_BR
dc.rightsrestritopt_BR
dc.subjectAverage value compensationpt_BR
dc.subjectGrid-connected power converterpt_BR
dc.subjectTime-delay compensation schemept_BR
dc.titleA simple dead-time compensation strategy for grid-connected voltagesourced converters semiconductor switches.pt_BR
dc.typeArtigo publicado em periodicopt_BR
dc.identifier.uri2https://www.sciencedirect.com/science/article/abs/pii/S037877961930166X?via%3Dihubpt_BR
dc.identifier.doihttps://doi.org/10.1016/j.epsr.2019.04.031pt_BR
Aparece nas coleções:DEELT - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_SimpleDeadTime.pdf
  Restricted Access
11,16 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.