Use este identificador para citar ou linkar para este item: http://www.repositorio.ufop.br/jspui/handle/123456789/10773
Registro completo de metadados
Campo Dublin CoreValorIdioma
dc.contributor.authorDiniz, Adriana Pedrosa-
dc.contributor.authorKozovits, Alessandra Rodrigues-
dc.contributor.authorLana, Cristiano de Carvalho-
dc.contributor.authorAbreu, Adriana Trópia de-
dc.contributor.authorLeite, Mariangela Garcia Praça-
dc.date.accessioned2019-02-28T13:40:35Z-
dc.date.available2019-02-28T13:40:35Z-
dc.date.issued2019-
dc.identifier.citationDINIZ, A. P. et al. Quantitative analysis of plant leaf elements using the LA-ICP-MS technique. International Journal pf Mass Spectrometry, v. 435, p. 251-258, 2019. Disponível em: <https://www.sciencedirect.com/science/article/pii/S1387380618302033>. Acesso em: 11 fev. 2019.pt_BR
dc.identifier.issn 13873806-
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/10773-
dc.description.abstractThe use of Laser Ablation coupled to Mass Spectrometry is a promising technique for analysis of plant tissue elements because it has advantages over conventional digestion techniques such as reduced levels of contamination and sample preparation time, possibility of spatial distribution analysis of elements, high number of repetitions, among others. This technique still has some limitations, especially with regard to calibration, which may result in inaccurate chemical analyses. The present study aims to compare two types of analyzers (quadrupole and magnetic sector field) regarding precision and accuracy. Certified material was examined, and also plant material analyzed by both solution in inductively coupled plasma optical emission spectrometry (ICP OES) and by laser ablation methods. It was observed that the magnetic sector field analyzer gave better results in relation to precision (relative standard deviation - RSD) and accuracy (recovery). An elemental composition pattern similar to that of the sample to be analyzed is relevant to validate the methodology for the analysis of leaves collected under different environmental conditions. Thus, pulverized Eremanthus erytropappus leaves were suggested as a second type of validation standard to be used in analyzes of plants belonging to the Atlantic and Cerrado Forest biomes.pt_BR
dc.language.isopt_BRpt_BR
dc.rightsabertopt_BR
dc.subjectQuadrupolept_BR
dc.subjectMagnetic sector fieldpt_BR
dc.subjectCalibrationpt_BR
dc.subjectPlant tissue analysispt_BR
dc.titleQuantitative analysis of plant leaf elements using the LA-ICP-MS technique.pt_BR
dc.typeArtigo publicado em periodicopt_BR
dc.identifier.uri2https://www.sciencedirect.com/science/article/pii/S1387380618302033pt_BR
Aparece nas coleções:DEGEO - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_QuantitativeAnalysisPlant.pdf
  Restricted Access
1,51 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.